Please follow the standard procedure of the Rockwell software to download configure the PLC and the network.

  • Click OK to add the NX-EIC202 to the network.
  • Please fill in according to your requirements.
  • The Connection tab of the New Module window gives the settings of RPI and the input type (Unicast/Multicast).
  • Set the data type to INT and select correct sizes (note Sysmac Studio indicates the size in bytes). Use the data as indicated in the I/O Allocation window (see section 2.3).
  • Please select the correct size of the input and output buffers in the Module Definition window.
  • Click on the Change … button to set the detailed IO data.
  • Enter the common data such as the Name, Description and IP address in the following form.
  • Select the NX-EIC202 from the list and click Create.
  • Select the New Module… function of the Ethernet item’s context menu.
  • Perform the following steps to add the NX-EIC202 to the network. Please see below an example of the main view of the tool. The main view of the RSLogix 5000 software provides the way to add the NX-EIC202 to the PLC’s network. The input and output tag sizes are necessary to configure the Ethernet/IP connection in RSLogix.
  • The I/O allocation indicates the input and output data sizes (in bytes) for the present configuration.
  • In the Multiview Explorer view, right-click the EtherNet/IP Coupler and select Display I/O Allocation from the menu.
  • rslogix 5000 software free download

  • Section 9-3 Transferring and Comparing SettingsĪfter the NX Configuration is finished, please use the following steps to check the resulting I/O Allocation size of the Coupler.
  • Section 9-2 Setting Slave Terminal Parameters.
  • The NX-EIC202 Operation Manual (see ) describes the procedure to configure the Slave Terminal (NX-EIC202 and the individual NX Units).Ĭonnect Sysmac Studio using USB connection and configure the NX configuration with the information of the following two sections of the original manual: Please find additional information about setting IP address in, section 9-4.Ģ.3 Setting up the Slave Terminal
  • Set the two rotary switches to the desired IP address (last octet 01 to FE for 192.168.1.1 to 192.168.1.254).Īfter a power toggle, the new IP address will be active in the Unit.
  • Perform the following steps to change the IP address of the Unit in the Rockwell default range (192.168.1.x).
  • To Install the new EDS file, select the Register an EDS file(s).
  • To delete the old EDS file, select the Unregister a device option.
  • Both installation as de-installation of the EDS file is done by the EDS Hardware Installation Tool (Tools menu). Set software IP address / Set NTP serverįollow the steps below to install (a new version of) an EDS file within RSLogix5000.

    rslogix 5000 software free download

    Installation: Install the EDS file in Logix5000Ĭonfigure the NX-EIC202 NX Configuration using Sysmac Studio Refer to the reference sections for details on the indicated steps. Use the following procedure to prepare the Unit for use.